| 1 |
Sanitary process piping |
Food, beverage, dairy, pharmaceutical, and clean-process fluid transfer |
ASTM A270 for sanitary tubing; ASTM A312 may apply to process pipe systems |
High in clean, mildly corrosive service |
Requires smooth internal surfaces, hygienic welds, complete drainage, regular cleaning, and removal of deposits. Chloride-bearing cleaners should be controlled. |
Excellent for hygienic environments when surface finish and cleaning procedures are properly managed |
| 2 |
General industrial process pipe |
Water, air, dilute organic chemicals, non-aggressive process fluids, and utility services |
ASTM A312 for seamless and welded austenitic stainless steel pipe |
Good in atmospheric and mildly corrosive conditions |
Design should account for fluid chemistry, temperature, stagnant zones, weld quality, and crevice formation. Periodic visual inspection is recommended. |
Very suitable for broad industrial utility and process applications |
| 3 |
Architectural and exposed service pipe |
Handrails, structural features, exposed drainage, façades, and decorative piping |
ASTM A554 for ornamental welded tubing; other ASTM specifications may apply to pressure service |
Good in rural and urban atmospheres; variable in coastal areas |
Regular washing helps remove salt, dust, and airborne contaminants. Surface scratches, carbon-steel contamination, and stagnant moisture can reduce appearance and service life. |
Excellent for appearance-focused applications away from severe marine exposure |
| 4 |
Water and low-chloride utility piping |
Potable water, cooling water, compressed air, and general plant utilities |
ASTM A312 or ASTM A778, depending on pipe construction and service requirements |
Good when chloride levels and water chemistry are controlled |
Monitor chlorides, temperature, flow velocity, and stagnant sections. Avoid prolonged exposure to concentrated disinfectants or deposits. |
Suitable for many water systems, but not a universal seawater or high-chloride solution |
| 5 |
Heat-exchanger and condensate piping |
Condensate return, low-to-moderate temperature heat-transfer circuits, and equipment connections |
ASTM A312 for pipe; ASTM A249 or ASTM A269 may apply when welded or seamless tubing is specified |
Good under controlled thermal and chemical conditions |
Control scaling, oxygen concentration, chlorides, and thermal cycling. Inspect welds and heat-affected zones where sensitization or localized corrosion may be possible. |
Good for moderate-duty systems with well-controlled water chemistry |
| 6 |
Chemical handling for mild media |
Dilute organic acids, selected alkaline solutions, alcohols, and non-chloride chemical services |
ASTM A312 or ASTM A358, subject to diameter, wall thickness, and fabrication requirements |
Conditionally good; strongly dependent on concentration and temperature |
Confirm compatibility using concentration-temperature data. Avoid assuming 304 is suitable for all acids, chlorides, bleach solutions, or reducing environments. |
Suitable only after a documented material-compatibility review |
| 7 |
Welded low-carbon 304L process pipe |
Fabricated process lines, vessels, manifolds, and systems with extensive welding |
ASTM A312 TP304L or ASTM A358 Type 304L, where applicable |
Good resistance with improved weld-zone corrosion control |
The lower carbon grade reduces the risk of chromium-carbide precipitation during welding. Proper heat input, post-weld cleaning, pickling, and passivation remain important. |
Preferred over standard 304 for many heavily welded assemblies |
| 8 |
Moderate-temperature exhaust and ventilation pipe |
Industrial ventilation, clean exhaust, kitchen exhaust, and selected thermal-air systems |
ASTM A312 or ASTM A554, depending on pressure, geometry, and finish requirements |
Good in dry or mildly corrosive exhaust |
Continuous high-temperature exposure can reduce mechanical performance and may promote sensitization. Evaluate thermal cycling, condensate chemistry, and insulation-related moisture. |
Suitable for moderate temperatures; high-temperature service requires engineering verification |
| 9 |
Underground or concealed service pipe |
Utility lines, building services, and protected process connections |
ASTM A312 or another project-specified ASTM stainless pipe standard |
Good only with suitable environmental protection |
Prevent contact with carbon steel, contaminated backfill, and chloride-rich moisture. Use appropriate supports, isolation, drainage, inspection access, and protective wrapping where required. |
Viable when installation details prevent crevice corrosion and external contamination |
| 10 |
General fabrication and custom pipe assemblies |
Skids, frames, low-pressure manifolds, instrument connections, and fabricated equipment |
ASTM A312, ASTM A778, ASTM A554, or ASTM A269 according to product form and service |
Good for general indoor and moderately corrosive environments |
Specify dimensional tolerances, weld procedure, surface finish, passivation, pressure testing, and traceability. Design out sharp crevices and stagnant pockets. |
Versatile and economical for many non-severe service assemblies |